• HUATEC GROUP CORPORATION
    bob
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    tom
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Leo
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
Người liên hệ : Noah
Số điện thoại : +8613911115555
WhatsApp : +8613910983110

X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm

Nguồn gốc Bắc Kinh
Hàng hiệu HUATEC
Chứng nhận ISO, CE, GOST
Số mô hình XXG-3205
Số lượng đặt hàng tối thiểu 1pcs
chi tiết đóng gói Gói ván ép xuất khẩu tiêu chuẩn
Thời gian giao hàng 1-4 ngày
Điều khoản thanh toán T/T, PayPal, Western Union
Khả năng cung cấp 500 chiếc mỗi tháng

Liên hệ với tôi để lấy mẫu miễn phí và phiếu giảm giá.

WhatsApp:0086 18588475571

WeChat: 0086 18588475571

Ứng dụng trò chuyện: sales10@aixton.com

Nếu bạn có bất kỳ mối quan tâm nào, chúng tôi cung cấp hỗ trợ trực tuyến 24 giờ.

x
Thông tin chi tiết sản phẩm
Sản lượng 170-320kv Nhập 2.5KW
Điểm lấy nét 2,5x2,5 Thâm nhập tối đa 55mm
Vật liệu Thép Góc bức xạ 40±5°
Sử dụng Kiểm tra X-quang công nghiệp, kiểm tra mối hàn, máy kiểm tra X-quang công nghiệp Nguồn cung cấp điện AC220V±10%,50HZ
Ứng dụng Kiểm tra X-quang công nghiệp, phát hiện mối hàn Bảo hành 12 tháng
Thời gian phơi sáng 5 phút Kích thước bộ điều khiển 350*290*170mm
kích thước máy phát điện 335×335×700mm Trọng lượng máy phát điện 43Kg
Bơm Vật gốm
Làm nổi bật

welding x ray machine

,

industrial x ray machine

,

x ray inspection equipment

Để lại lời nhắn
Mô tả sản phẩm

320KV Ceramic tube penetrant 40mm Directional Radiographic inspection machine

 

 

 

Main technical parameters

 

ITEM

XXG3205
Max Penetration thickness Steel (A3) 55mm
Focal Distance 600mm
Exposure Time 5min
Film Type Agfa D7

Double lead foil Intensifying screen

0.03
Darkroom Disposal 20±2℃
Development 5minutes
Blackness 1.5
Input Voltage (V) 220V±10% 50―60Hz
Capacity (KVA) 3.2
Output Tube voltage (KVP) 170-320Kv
Tube current (mA) 5
Stability ±1%

X-RAY

Tube

Focus mm2 2.5×2.5
Radiation Angle 40±5°
Sensitivity k≤1.8%
Operation Mode Intermittent operation, Radiating time to cooling time is 1:1

X-Ray

Controller

Dimension 350×290×160
Weight 11kg
Circuit Structure Micro-computer control ,Modular structure,Voice prompt

X-RAY

Generator

Cooling Force air cooling
Insulation SF6 Gas Insulation
Working Pressure 0.35Mpa-0.45Mpa
Dimension 335×335×700
Weight (kg) 43kg
Working Temperature -10℃―+40℃

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Delivery

Directional glass X-ray tube 1 Pcs  
Generator 1 Set  
High voltage joins cable 1 Pcs 25 Meters
Controller 1 Set  
Power cable 1 Pcs 10 Meters
Grounding cable 1 Pcs 5 Meters
Accessories 1 Set  
(Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc)

X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm 0
 X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm 1X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm 2
 

System Installation

1.Check and count all goods to be received per the packing list. And then check the quality of the parts for damage,lost and mistake.

2.Keep the controller in a flat,dry and dustless place, switch off the power and connect the power cable.

(Note:

The power supply of the unit is single phase 220V±10% 50-60HZ)

3.If necessary,one end of earth wire can be connected to the earth terminal of the controller and the other end to the special grounding wire.

4.Connect controller to x-ray generator by special 9 cores cable,and form better contact.

5.Check the gas pressure gauge on x-ray generator and make sure it range from 0.35Mpa to 0.45Mpa.If not,the unit is not allowed to turn on so as to avoid any damage to the x-ray generator.

 

Working Principle

This machine is composed of intelligent controller-ray generator, power cable and connecting cable.

1.The controller will consist of the following sections:

Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)

Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.

Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.

2.The x-ray generator will consist of the following sections:

X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling fan etc.

3.The schematic diagram of the complete machine:

 

Optional accessories:

Testing platform, IQI/wire penetrameter, lead letter/digits, lead tape, Cassette, lead screen, personal dosimeter, film viewer, densitometer, film developer, dark room light, RT calibration block etc.

 

X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm 3X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm 4X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm 5